Dedicated Circuit: 1 Load

callout

Sense can easily monitor a single 120V or 240V circuit. As a reminder, this feature is designed to monitor circuits that have a single device or appliance on them. If you monitor a circuit with multiple devices, they will show as a single device in the Sense app.

What do you want to monitor?

Monitoring a single 120V load

Monitoring a single 240V load

Monitoring a 120V load

Instructions:

1. Turn off the breaker to the load.

2. Clamp one Flex sensor around the single ungrounded conductor attached to the breaker. Tuck the other Flex sensor away safely within your electrical panel.  

The direction of the Sense logo sticker on the sensor must face the circuit breaker. 

Ensure the breaker is still in the ‘off’ position before returning to the core installation guide.

Monitoring a 240V load

Instructions

1. Turn off the breaker to the load.

2. Clamp one Flex sensor around either ungrounded conductor attached to the breaker. It does not matter which conductor the sensor is attached to.

3. Clamp the other Flex sensor around the remaining ungrounded conductor attached to the breaker. 

The direction of the Sense logo sticker on each sensor must face the circuit breaker. 

Ensure the breaker is still in the ‘off’ position before returning to the core installation guide.