Installation Instructions

Wiser Energy with Dedicated Circuit Monitoring

load-full-2loads-SE

Safety Precautions

Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

danger-alert Created with Sketch.

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70, CSA Z462, or NOM 029-STPS.

This equipment must only be installed and serviced by qualified electrical personnel.

Turn off all power supplying this equipment before working on or inside equipment.

Always use a properly rated voltage sensing device to confirm power is off.

Replace all devices, doors, and covers before turning on power to this equipment.

Beware of potential hazards, and carefully inspect the work area for tools and objects that may have been left inside the equipment.

Failure to follow these instructions will result in death or serious injury.

The Wiser Energy System has been tested and certified for use with Square D™ circuit breakers, load centers and combination service entrance devices (CSEDs) as installed per this manual.

For use in non-Square D load centers and CSEDs please consult with the manufacturer for compatibility.

Specifications

Technical Specifications

Wiser Energy is a home energy monitoring device. It is used to measure the current and voltage on the service mains. The device monitors two phases of 120 VAC. If installed outside, it must be kept dry and within specified temperature ranges.

Current Sensor Specifications

CAT IV 250 V 200 A max
Cable length: 46 in. | Inside diameter: 0.95 in.
May be used on uninsulated conductors

Monitor Specifications

Compatibility: 120 VAC (90 V–130 V)
Power Use: < 5 Watts, 0.1 amps
Wi-Fi: 2.4 GHz 802.11b/g/n
Size: 137 mm x 66 mm x 32 mm
Weight: 200 g

Climate Specifications

RH <90%; IPx0 rating
Temperature: 32 – 154.4 ºF (0 – 68 ºC)
Elevation < 6,561 ft. (<2,000 m)

Legal

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation is subject to these conditions:

1. It may not cause harmful interference.

2. It must accept any interference received, including interference that may cause undesired operation. If it is not installed and used as per the instructions, it may cause interference which is harmful to wireless communications. There is no guarantee that interference will not occur in a particular installation. If it does cause interference we recommend: reorienting or relocating the receiving antenna, or increasing the separation between the device and the receiver.

3. Patents: sense.com/patents

Certified to CSA STD C22.2 No. 61010-1
Conforms to UL STD 2808
Conforms to UL STD 61010-1
Conforms to UL STD 61010-2-032
Conforms to CAN ICES-3(B)/NMB-3(B)

Wiser Energy components 

Wiser Energy Monitor

Current Sensors

Current Sensors

Power Cable

Antenna Assembly

Mounting Bracket (optional)

Instructions

In addition to monitoring your entire home at the mains, Wiser Energy can also track up to two specific circuits. This setup is designed to monitor circuits with only a single device attached. If multiple devices are present on a circuit, they will appear as one device in the Sense app.

New Users

Follow all steps, starting at step 1.

Existing Users

Follow all steps with a  success  icon, starting at step 1.

success  01 Open the middle port

Already have Wiser Energy installed? Skip to step 2 to remove power to the Wiser Energy monitor before opening the middle port.

Using a flathead screwdriver, pry open the cap on the middle port of the Wiser Energy monitor. This will be used to connect the second set of sensors to monitor your dedicated circuits. 

success  02 Turn OFF power

Installation of the Wiser Energy System requires removal of all power. Be sure to provide an alternate light source before beginning the installation procedures. Do not begin the installation procedures until all power is completely removed from the equipment including any alternate power sources.

1. Turn OFF the main feeder disconnects that supply power to both electrical panels, or if the installation uses the revenue meter for isolation, arrange for the utility provider to remove power. If a main feeder disconnect is not present and the revenue meter cannot be used as an isolation device, contact the utility company for removal of power.

2. Turning OFF only the main circuit breaker is insufficient to remove power completely from the panel. Line side connections will still be live.

3. Apply the appropriate lockouts to the disconnecting means.

4. Turn OFF all alternate power sources connected to the equipment.

success  03 Remove panel covers

1. Apply appropriate PPE.

2. Remove the cover screws and remove the load center cover from each panel.

3. Measure the voltage from each line to neutral and from line to line to confirm that all power is OFF.

04 Find a spot for the Wiser Energy monitor

Already have Wiser Energy installed? Skip to step 8.

The Wiser Energy monitor is designed to fit within one of your panels in order to monitor a home’s energy consumption.

Note: If there is no open space available, use an external enclosure following NEC® and local standards.

05 Install the antenna

Using the back of a screwdriver, punch out the knockout cover in the electrical panel. Then, insert the antenna.

DANGER

HAZARD OF ELECTRIC SHOCK EXPLOSION, OR ARC FLASH

Maintain 1 in. (25mm) minimum separation between the monitor and antenna extension assembly to load center parts (bus, stabs, circuit breakers, and power wires).

Failure to follow these instructions will result in death or serious injury.

06 Connect

In the same panel the Wiser Energy monitor is located, connect the power cable, antenna, and current sensors to the monitor. Be sure to insert the sensor into the outer port.

07 Clamp sensors around service mains

As a precaution, first plug the sensors into the Wiser Energy monitor.

In the panel where the Wiser Energy monitor is located, clamp the current sensors around the service mains so that both Wiser Energy labels face the same direction. The direction of the labels on the sensors should face the power source. Once placed in the final orientation, push the sensor lock in until you hear a click.

As a precaution, first plug the sensors into the Wiser Energy monitor.

success  08 Connect second set of sensors to middle port

Connect the second set of sensors to the middle port on the monitor.

Follow local code and best practices for interconnecting multiple electrical panels.
success  09 Connect sensors to dedicated circuits

Wiser Energy can monitor up to two dedicated devices on 120 or 240V circuits. Please follow the instructions below relevant to your installation. You’ll return to this page to finish installation.

Monitoring a single load?
Monitoring two loads?
10 Connect the power wires

Already have Wiser Energy installed? Skip to step 11.

(compatible with Square D 15 – 30 A thermal magnetic circuit breakers).

Dedicated Circuit Breaker Method

In the panel where you placed your Wiser Energy monitor, add a new Square D brand two-pole 15 – 20 A circuit breaker into the load center. With circuit breaker OFF, connect the black power wire to one circuit breaker terminal and connect the red wire to the other terminal.

Two Wire Rated Lug Method

Existing Square D brand 15 – 30 A thermal magnetic two-pole circuit breakers in the load center have terminals that can accept two conductors. With the circuit breaker OFF, use half of the clamp plate for load wire and the other half for Wiser Energy power wire.

Pigtail Wire Method

With the circuit breaker OFF, create a splice connection to the two-pole circuit breaker following the NEC and circuit breaker manufacturer guidelines for splice connector type and wire size.

Note: For all three methods, attach a white wire to an appropriately sized terminal on the neutral bus bar.

success  11 Close the panel covers

Replace the panel covers carefully to ensure that there is no pressure on the current sensor clamps that would cause them to open. Label the Wiser Energy circuit breaker with the included sticker.

success  12 Turn power on, wait for chime

Once both panels are closed, restore power to the panels and listen for one minute for one of the following sounds:

Visit help for troubleshooting.

successSuccess Chime: Installation was successful!

success Repeating Beep: There is an installation problem. Check cable connections.

success No Sound: The Wiser Energy monitor cannot start. Check power cable connections.

success  13 Use the app to complete setup

Install the Sense app. Tap “Get Started” and follow the on-screen instructions. The app will guide you through the Wi-Fi setup and account creation process.

Upgrading standard setup to monitor dedicated circuits?
Go to Settings / My Home / Connected Devices and select “Dedicated Circuit Monitoring” within Sensor Sources.